| Error Code | Description | Troubleshooting Steps | | --- | --- | --- | | E0 | Indoor unit communication error | Check the communication cable, ensure it is securely connected | | E1 | Outdoor unit communication error | Check the communication cable, ensure it is securely connected | | E2 | Indoor unit temperature sensor error | Check the temperature sensor, ensure it is clean and securely connected | | E3 | Outdoor unit temperature sensor error | Check the temperature sensor, ensure it is clean and securely connected | | E4 | Indoor unit EEPROM error | Reset the AC, if issue persists, contact a technician | | E5 | Outdoor unit EEPROM error | Reset the AC, if issue persists, contact a technician | | E6 | Indoor unit fan motor error | Check the fan motor, ensure it is clean and securely connected | | E7 | Outdoor unit fan motor error | Check the fan motor, ensure it is clean and securely connected | | E8 | Indoor unit compressor error | Check the compressor, ensure it is clean and securely connected | | E9 | Outdoor unit compressor error | Check the compressor, ensure it is clean and securely connected | | EA | Indoor unit drain pump error | Check the drain pump, ensure it is clean and securely connected | | Eb | Outdoor unit drain pump error | Check the drain pump, ensure it is clean and securely connected |
Use specific Google search strings to find the PDF: godrej split ac error code list pdf
| Error Code | Meaning | Possible Cause | |------------|---------|----------------| | | Indoor PCB (circuit board) sensor fault | Loose wiring, faulty sensor, PCB failure | | E2 | Indoor coil temperature sensor error | Sensor disconnected or damaged | | E3 | Outdoor coil sensor error | Outdoor unit sensor failure | | E4 | Room temperature sensor error | Thermistor faulty | | E5 | Outdoor PCB communication error | Wiring issue between indoor & outdoor units | | E6 | Fan motor error (indoor/outdoor) | Jammed fan, motor capacitor blown | | F1 | High pressure protection | Dirty condenser coil, overcharged gas | | F2 | Low pressure protection | Refrigerant leak, clogged filter | | F3 | Discharge temperature sensor error | Outdoor unit sensor issue | | F4 | IPM (Intelligent Power Module) protection | Overheating, voltage fluctuation | | H1 | Defrost mode active (normal in winter) | Unit removing frost – not a fault | | C5 | Compressor overcurrent | Low voltage, failing compressor | | U1 | Refrigerant overcharge | Too much gas in system | | Error Code | Description | Troubleshooting Steps