features a 7-inch full-color touchscreen with built-in operating instructions and customizable cycle modifiers. Learn about Quantum Gold capabilities
A hotel client wants a sanitize cycle above 150°F. Solution: In programming mode, assign P20 (Hot Fill Temp) to 160°F, then increase P30 (Wash Time) to 20 minutes. Warning: Ensure your facility has a booster heater capable of maintaining this temp. speed queen quantum programming manual
To prevent unauthorized changes, Speed Queen machines require a physical "key" to enter the back-end settings. speed queen quantum programming manual
Adjusting the "vend" price is the most common reason to access the manual. Speed Queen & Hubesch Stack Dryer Programming speed queen quantum programming manual